BX6 Pro-Cleaning and Maintenance

Packing List

pic-1

Use of the Product

Function Description

pic-2

Vacuum + Tap + UV Mode

After power on, the anti-mite vacuum cleaner starts with Vacuum + Tap + UV mode by default, the corresponding indicator light will be on, and the machine will start vacuuming function, brushroll tapping function, the UV light dust mite-removal function and the negative ion function. 

Vacuum + Tap Mode

When the machine is in Vacuum + Tap + UV Mode, press mode button once to change to Vacuum+Tap mode. Corresponding indicator will be one and the machine will start vacuuming function, brushroll tapping function and the negative ion function.

Vacuum + UV Mode

When the machine is in Vacuum + Tap Mode, press mode button once, press mode button once to change to Vacuum + UV mode. Corresponding indicator will be one and the machine will start vacuuming function, the UV light dust mite-removal function and the negative ion function. 

Dust Level Display

When the cleaned surface is in a clean state, the dust level bar is blue. When it is in a dirty state, the dust level bar is red.When it is in a slightly dirty state, the dust level bar is yellow. As the dust level increases, the dust level bar slowly changes from blue to yellow, and finally to red. As the dust level decreases, the dust level bar slowly changes from red to yellow until it is all blue. 

Brushroll Blockage Indicator

This indicator flashes when the brushroll is blocked.

Cleaning and Maintenance

Note:
1. HEPA filter is available for sale at JIMMY distributor.
2. It is recommended to clean the dust cup in time after each use. When there is too much dust to cause HEPA blockage, it needs to be cleaned in time or replaced if necessary.

Cleaning of Dust Cup

Turn off the product, remove the dust cup according to the instruction label on the dust cup; Align the dust cup with the garbage can, press the bottom cover release button, open the bottom cover, and pour out the garbage. (Figure 1)

HEPA Filter Cleaning

Hold the dust cup with one hand and pull out the filter assembly with the other hand.Turn HEPA bottom cover clockwise; Take out the HEPA assembly downward, tap the HEPA assembly downward to clean the dust, or use a brush to clean the dust and other debris on the HEPA assembly. (Figure 2 -Figure 4)

pic-3

After cleaning the dust cup and HEPA assembly, put the HEPA into the filter assembly and then rotate it anticlockwise to fix it. After the "click" sound is heard when rotating, and the HEPA is assembled in place without loosening.Then put the filter assembly back into the dust cup and press it to the bottom, the dust cup assembly is in place.

Note:
1. Do not miss HEPA filter!
2. If too much dust is accumulated in the dust cup, clean the dust cup and filter assembly with water, and wipe them with dry cloth. Pay attention that HEPA filter need to be washed as less as possible. Clean the dust and foreign matters on HEPA filter by tapping, and ensure that the dust cup and filter assembly are completely dry before installation.

pic-4

Brushroll Cleaning and Assembly
Note:

When cleaning the brushroll, be sure to disconnect the power supply to prevent the brushroll from starting by mistake and cause human injury.

Turn off the machine, unplug the power supply, push the brushroll cover latch. Turn it from the closed state to the open state, and then remove brushroll cover and take out brushroll. Clean brushroll with cleaning brush. After cleaning the brushroll, install the brushroll and brushroll cover back to mainbody in turn, and lock the brushroll latch. (Figures 5)

Maintenance and Storage

Please clean dust cup and HEPA filter after each use for further use. It is recommended to replace a filter after 30-50 hours of working time(depending on specific situation) for better use. Any paper, lead glass, plastic will greatly affect the effect of UV light. Dust or stain on UV light cover will affect the effect of UV light. Please wipe and clean the UV light cover regularly for better use.
Do not touch the UV light cover as dirt will affect UV light effect.
Put the machine in cool and dry place if the machine is to be idled. Do Not leave it in direct sunlight or humid environment.