Chapter 1 Product Installation
Parts Name
Packing List
Chapter 2 Use of the Product
Function Description
1. The indicator of Tap, UV, Sterilization, Ultrasonic wave indicator will be stay light on after turning on the machine. Dust concentration index display (display range 0-99): When the cleaning surface has less dust, the dust index shows from 0 to 30. When the cleaning surface has medium dust, the dust index shows from 31 to 60. When the cleaning surface has much dust, the dust index shows from 61 to 99. The dust index value and the dust concentration light strip change according to dust concentration. When dust concentration increases, the dust index value increase and the light strip fades from white to red . When dust concentration decreases, the dust index value decrease and the light strip fades from red to white.
2. Insert the plug into the socket, press on/off button, the machine is in strong mode by default and strong indicator lights up. Press the mode button to switch the soft mode and soft indicator lights up, strong indicator lights off. Press the mode button again to switch back to strong mode.
3. The heating function is switched on by default when turn on the machine and the heating indicator lights up. Long press the mode button for 3 seconds to switch off the heating function and the heating indicator lights off. Long press the mode button for 3 seconds again to switch on the heating function.
4. Press the on/off button again when turned on, the machine stops working and all the indicators light off.
Note
1. When the dust over the Max line, please clean the dust cup and MIF filter in time.
2. For safety reasons, the UV light only works when two micro switches are pressed simultaneously. Otherwise, the UV light will automatically turn off.
3. The product is equipped with UV light.Do not view the bottom of the machine, shine on plants when the power is turned on to prevent UV rays from causing harm to human body or other objects.
4. Do not touch the hot air outlet on the bottom of the machine in case of hand scald after the heating function turned on. After machine turns off, there is still remain high temperature on the hot air outlet, also please do not touch it with your hands.
Chapter 3 Cleaning and Maintenance
Dust Cup Cleaning
1. Turn off the machine and unplug the power cord. Then press the release button and lift upward.
2. Hold the dust cup and dust cup lid separately, twist dust cup lid according to the arrows instruction on dust cup, lift up and remove it from dust cup to clean.
Note
1. MIF filter is available for sale at JIMMY distributor.
2. It is recommended to clean the dust cup in time after each use. When there is too much dust to cause MIF blockage, it needs to be cleaned in time or replaced if necessary.
MIF Filter and Cyclone Cleaning
1. Hold the cyclone in one hand, pinch the "UP" logo with the other hand, and take out filter. Do Not tap the filter in reverse side in case of filter clog. Clean the cyclone metal filter and plastic parts with the attached mini brush.
2. After cleaning dust cup, MIF filter and cyclone, assemble in reverse order. Rotate the dust cup cover assembly into the dust cup. After hearing a "click" and the mark is aligned with the lock position that is assembled in place.
Note
1. Do Not miss the MIF filter!
2. If too much dust is accumulated in the dust cup, clean the dust cup and filter assembly with water, and wipe them with dry cloth. Pay attention that MIF filter need to be washed as less as possible. Clean the dust and foreign matters on MIF filter by tapping, and ensure that the dust cup and filter assembly are completely dry before installation.
Brushroll Cleaning and Installation
1. Turn off the machine, unplug the power supply, push the brushroll cover latch. Turn it from the closed state to the open state, and then remove brushroll cover and take out brushroll. Clean brushroll with cleaning brush.
2. After cleaning the brushroll, install the brushroll and brushroll cover back to mainbody in turn, and lock the brushroll latch.
Note
1. For safety reasons, please turn off the machine and unplug power cord before cleaning brushroll.
Maintenance and Storage
● Please clean dust cup and filter after each use for further use.It is recommended to clean immediately when there is too much dust in dust cup.
● It is recommended to replace a filter after 30-50 hours of working time(depending on specific situation) for better use.
● Any paper, lead glass, plastic will greatly affect the effect of UV light. Dust or stain on UV light cover will affect the effect of UV light. Please wipe and clean the UV light cover regularly for better use.
● Do not touch the UV light cover as dirt will affect UV light effect.
● Put the machine in cool and dry place if the machine is to be idled. Do Not leave it in direct sunlight or humid environment.